FROM OUR PRODUCT RANGE

DV

  • Voltage Range 1200 – 6400V RMS nominal
  • Technology Insulation Digital Technology
  • Output ±50mA current
  • Insulation Test Voltage 18.5 kVRMS / 50Hz / 1min
  • Response Time 60µs
  • Operating Temperature -40°C to +85°C (DV 6400: to +70°C)

Compact IDT voltage sensors for medium to high voltage traction measurement and the first in the market rated to DC Class 1 accuracy. Bipolar and insulated measurement up to 7360V peak; ±50mA current output; ±15 ~ ±24V supply; footprint compatible with OV, CV4, and LV 200-AW/2 series for drop-in replacement. Connection configurations vary by model: cable input/output on DV 1200 and DV 2000; cable input with M5 stud/Faston output on DV 1500; M5 stud input and M5 stud/Faston/safety nut output on DV 6400. Compliant with EN50155 (traction), EN50121-3-2 (railway EMC), EN50124-1 (insulation), and IRIS.

Applied in single and three phase inverters, propulsion and braking choppers, propulsion and auxiliary converters, high power drives, substations, and onboard energy meters in fixed and onboard railway installations.

Overview
RELATED PRODUCTS

While you are here

ATO
  • Technology Air-core split core CT, Ferrite core
  • Standard IEC 61869-2 Smart Grid
AHR
  • Nominal Ranges 500 – 2000A True RMS
  • Technology Open Loop Hall Effect
AK/AKR
  • AK Range 2 – 200A (jumper selectable)
  • AKR Range 2 – 2000A (jumper selectable)
AP/APKR
  • Nominal Ranges 0 – 400A
  • AP Output Type Average (sinusoidal loads)
Scroll to Top