4700 Precision High Voltage Meter
4700
- DC Accuracy 0.03%
- AC Accuracy 0.12% True RMS
- Direct Measurement Range Up to 10KV DC or AC
- Extended Range (SmartProbes) Up to 140KV
- AC Frequency Range 0.01 Hz – 600 Hz
- Readings 60 filtered per second
Vitrek’s 4700 measures high voltage directly to 10KV DC or AC without external probes, with 0.03% DC accuracy and 0.1% True RMS AC accuracy that rivals traditional high voltage reference dividers. For production lines, calibration labs, and research facilities where high voltage measurement accuracy is the thing you cannot compromise on.
The 4700 is built around DSP technology that takes over 40,000 raw readings per second: filtered, sub-sampled, scaled, and offset-corrected, delivering 60 high-accuracy readings per second with rock-solid stability on both AC and DC simultaneously. A colour touchscreen displays both AC and DC content at the same time and can plot readings from a few seconds to several days in chart mode, documenting HV drift, ramp time, overshoot, and sag on a single screen.
SmartProbe™ inputs extend the direct 10KV measurement range to 35KV, 70KV, 100KV, and 140KV without recalibration. Each SmartProbe stores its own calibration data, which downloads automatically when connected. The SmartProbe’s ultra-low temperature coefficient attenuator design minimises self-heating, and lower capacitance construction improves AC performance at high frequencies. Use one probe to extend measurement range, or use two probes simultaneously for high voltage differential or phase-to-phase measurements.
True RMS AC measurement covers 0.01 Hz to 600 Hz, from VLF (very low frequency) cable and transformer testing through to 400 Hz aviation frequency testing, with 78dB AC noise rejection for stable 6-digit DC readings in electrically noisy environments. Peak-to-peak, crest factor, and fundamental frequency measurement are all included.
Applications include calibrating hipot testers, HV power supplies, insulation testers, and HV transformers. High-impedance G-series SmartProbes extend capability to electrostatic voltmeter applications with input impedance up to 30GΩ. An optional battery pack provides up to 11 hours of portable operation.
Ethernet, Serial, and USB printer port standard. GPIB optional. ISO-17025 accredited calibration certificate included with every instrument and probe.
Overview
The 4700 is Vitrek’s precision high voltage meter: 0.03% DC accuracy, direct measurement to 10KV, and SmartProbe extension to 140KV, in a compact benchtop instrument. The calibration lab choice when high voltage measurement accuracy matters and the traditional reference divider is too fragile, too slow, or too much trouble.
Specifications
- DC accuracy: 0.03%
- AC accuracy: 0.12% True RMS
- Direct measurement range: Up to 10KV DC or rms AC
- Extended range (SmartProbes): 35KV, 70KV, 100KV, 140KV
- AC frequency range: 0.01 Hz – 600 Hz (VLF to aviation)
- AC noise rejection: 78dB
- Readings: 60 filtered per second (40,000+ raw)
- Dual probe inputs: Differential or phase-to-phase measurement
- Chart mode: Plots from seconds to days
- Battery option: Up to 11 hours (optional battery pack)
Additional Information
- Applications: Hipot tester calibration, HV power supply calibration, insulation tester calibration, HV transformer testing
- SmartProbe types: HVL-series (lab grade), HVP-series (handheld portable), G-series (high impedance, electrostatic applications, up to 30GΩ)
- Calibration: ISO 17025 accredited certificate included with instrument and probes (A2LA accredited)
- Interfaces: Ethernet, Serial, USB printer port standard; GPIB optional
- Made in USA
RELATED PRODUCTS
While you are here
964i
964i High Voltage Switching System- Max Voltage Up to 15KV DC / 10KV AC
- Max Current 40A (HC Series cards)
XiTRON XT2640
XiTRON XT2640 Multi-Channel Harmonic Power Analyzer- Power Accuracy 0.03%
- Virtual Power Analyzers Up to 3 (in single chassis)
PA900
PA900 Precision Multi-Channel Harmonic Power Analyzer- Power Accuracy 0.03%
- Bandwidth 1 MHz
PA910
PA910 High Accuracy Multi-Channel Harmonic Power Analyzer- Power Accuracy 0.045%
- Bandwidth 5 MHz